RFC 176 UNKNOWN ARPANET · BYTE SIZE

Comments on "Byte size for connections"

Three views on who should choose a connection's byte size.

On rfc-editor.org ↗
PUBLISHED
June 1971
AUTHORS
A.K. Bhushan, R. Kanodia, R.M. Metcalfe, J. Postel
STREAM
Legacy
BYTE SIZES MENTIONED
1 through 255
TELNET DATA
8-bit ASCII characters
ICP DATA
32-bit socket numbers
DOI
10.17487/RFC0176

RFC text

Original text · RFC Editor View on rfc-editor.org ↗
Network Working Group                          A. Bhushan, MIT
Request for Comments #176                      R. Kanodia, MIT
NIC #7100                                      R. Metcalfe, MIT
Categories: C and D                            J. Postel, UCLA
                                               14 June 1971



                 Comments on Byte Size for Connections
                 -------------------------------------



     There are at least the following three views on the use of
byte size for network connections*:

     1)   Byte size should not be used at all.

     2)   Byte size is solely for the convenience of NCP's.

     3)   Byte size choice is a user-level prerogative.


     According to the first view, network connections are bit
streams, and messages should contain bit counts (i.e., a
byte size of 1).  This view existed before the "Glitch Cleaning"
of RFC 107, and was discarded in favour of byte stream because
of stated reasons of efficiency in storage management and
message concatenation.

     The second view represents a special interpretation of
RFC 107.  According to this interpretation, byte size is
entirely a 2nd level (i.e., NCP) issue.  There is no require-
ment that 3rd level user processes be able to specify byte size.
This view is indicated in RFC 151 by Shoshani.





----------------------
* Byte size for connection is the byte size selected by
sending NCP, as explained in RFC 107 (Output of Host-Host
Protocol Glitch Cleaning Committee).

     According to the third view user processes are always
allowed to choose byte size for connection, either explicitly
(specify a specific byte size parameter) or implicitly (byte
size depends on I/O mode).  An NCP is allowed to use a default
byte size, if the user does not specify it.


                            The Correct View
                            ________________


     The third view should be considered the correct interpre-
tation of RFC 107.  In fact, RFC 107 states on page 2, "the
choice of the byte size for a connection is a 3rd level protocol
issue."   To be consistent with TELNET, ICP, and other 3rd
level protocols which require that a specific byte size be
used for connection, it is imperative that corresponding 3rd
level processes be able to specify (and_impose) a particular
byte size to the NCP.  NCP implementors should take note of it.


         On Specifying Fixed Byte Sizes in 3rd Level Protocols
         -----------------------------------------------------


     Holding the view that byte size choice is a 3rd level
issue, we are still faced with the following two questions.
First, is it appropriate for 3rd level protocols to legislate
a specific byte size for all connections using that protocol?
Second, if it is appropriate to specify byte size, then what
should this choice be?

     There are two arguments in favour of using specific
byte size in 3rd level protocols.  First is that a potential
mismatch problem exists because RFC 107 does not require
that NCPs be capable of handling all byte sizes 1 through 255.
Using a fixed byte size of 8-bits or 8-bit multiples resolves
the problem as this is acceptable to all hosts (including
terminal IMPs).



     The second argument is one of efficiency.  If it is agreed
before hand that only a specific byte size would be used,
it is possible to make programs more efficient (i.e., reduce
program space, and possibly run time).  The efficiency argument
assumes that the byte size for connection represents the natural
byte structure of data being transferred over the connection.



     For TELNET and ICP, the byte size choice is straight
forward as data is naturally in 8-bit multiples (8-bit ASCII
characters in TELNET, and 32-bit socket numbers in ICP).  But
for data transfer protocols, the byte size choice is more complex,
as data may be structured in a variety of byte sizes.  Specifying
a byte size for a data transfer connection reduces efficiency
in instances where connection byte size does not correspond
to data byte size.  Further, filler fields will be required
for data blocks which are not a multiple of the fixed byte
size.  This imposes an additional overhead.

     Even if all hosts were to accept arbitrary byte sizes,
and the 3rd level protocol does not legislate a specific byte
size, the inefficiency problem will not be solved entirely.
Under current specifications "the byte size is fixed for the
life of a connection".*  This means that byte size cannot be
varied during the life of a connection even if structure of
data varies.  The problem of inefficiency is solved only for
instances in which data has a constant byte structure.



     Given the current state of the network, it appears that
specifying fixed byte size in 3rd level protocols is a good
idea.  This eliminates the potential byte size mismatch problem,
and improves efficiency at least for TELNET and ICP.  In data
transfer, the efficiency issue is more complex, as discussed
earlier.  It is not clear that overall efficiency would be
degraded if a fixed byte size was required.



                    On Reopening the Byte Size Issue
                    --------------------------------



     The above discussion exposes certain weaknesses in the
efficiency arguments for having byte streams on network connec-
tions.  In moving from bit stream to byte stream, we may have
lost generality, and it is not clear how much overall efficiency
is gained.  Sometimes, the gain in NCP efficiency may be at the
expense of user process efficiencies.








--------------------

*    RFC 107, page 2

     It is also clear that for efficiency arguments to hold,
the byte size choice should not be an NCP prerogative.  It
is the combined efficiency, rather than NCP efficiency which
should be our primary concern.  Restricting byte size choice
to NCPs has the further disadvantage of potential byte size
mismatch not only between communicating NPCs but also at the
user-NCP interface.  Therefore, allowing a user process to
specify byte size is a step in the right direction, given
that we have adopted byte streams.

     It is our opinion that the issue of bit stream and byte
stream be set aside until serious consideration can be given
to a major Host-Host Protocol overhaul.  At a later stage
we will have a better idea of the relative efficiency merits.









       [ This RFC was put into machine readable form for entry ]
       [ into the online RFC archives by BBN Corp. under the   ]
       [ direction of Alex McKenzie.                   12/96   ]

ISO Plain Language

On this page
PROBLEMRFC 107 left open who should choose a connection's byte size: the NCP or the user-level process.
MECHANISMThe authors compare three views and argue that a user process should be able to specify the size, while third-level protocols may set a fixed size where useful.
THE CONCLUSIONThe RFC recommends leaving the broader bit-stream versus byte-stream question for a major Host-Host Protocol review.

§1Three Views of Byte Size

The RFC describes three views: connections should be bit streams with no byte size, byte size should be chosen only for NCP convenience, or users should control byte size. The first view had been set aside in favor of byte streams for reasons of storage-management and message-concatenation efficiency.

Under the third view, a process may choose a byte size explicitly or implicitly through its input/output mode. An NCP may use a default when the process makes no choice.

The debate is about who chooses the size of each unit of data. The authors favor letting the program using the connection choose, or use a default when it does not specify one.

§2Why User-Level Choice Matters

The authors say RFC 107 treats byte-size choice as a third-level protocol issue. TELNET and the Initial Connection Protocol (ICP) require particular byte sizes, so their user-level processes need to be able to specify that choice to the NCP.

If the NCP alone chooses, the byte size can mismatch both between communicating NCPs and between an NCP and its user process.

A protocol that needs a particular byte size should be able to request it. Otherwise, its data may not fit the size chosen below it.

§3When Protocols Fix a Byte Size

The RFC gives two arguments for fixing a byte size in a third-level protocol. RFC 107 does not require every NCP to support every size from 1 through 255, while 8-bit sizes or multiples of 8 are acceptable to all hosts, including terminal IMPs. A known size may also reduce program space and possibly running time.

TELNET data consists of 8-bit ASCII characters, and ICP carries 32-bit socket numbers. Data-transfer protocols are less straightforward: a fixed size can reduce efficiency when the data has another structure, and filler fields may be needed. The size also stays fixed for the connection's life.

A fixed size can make some protocols simpler and more efficient. It can also waste space when the data naturally uses a different size.

§4Reopening the Bit-Stream Question

The discussion questions whether byte streams gained enough overall efficiency to justify losing the generality of bit streams. It says the combined efficiency of user processes and NCPs matters more than NCP efficiency alone.

The authors recommend setting the issue aside until a major Host-Host Protocol overhaul can examine it.

The authors are not sure byte streams improve efficiency overall. They recommend revisiting that question during a broader protocol review.

§5References