IMPSYS change notification
IMP system version 2513 lengthens host startup delay and adds interface testing.
Cosell, B., "IMPSYS change notification", RFC 256, DOI 10.17487/RFC0256, November 1971, <https://www.rfc-editor.org/info/rfc256>.
@misc{rfc256,
series = {Request for Comments},
number = 256,
howpublished = {RFC 256},
publisher = {RFC Editor},
doi = {10.17487/RFC0256},
url = {https://www.rfc-editor.org/info/rfc256},
author = {B. Cosell},
title = {{IMPSYS change notification}},
pagetotal = 1,
year = 1971,
month = nov,
} RFC text
Network Working Group B. Cosell
RFC #256 BBN
NIC #7697 3 November 1971
Categories: B.1
Updates: None
Obsoletes: None
IMPSYS Change Notification
We will shortly install (or perhaps will have already
installed) a new version of the IMP system, Version 2513. The
new version incorporates two principal changes:
1. A Host will be prevented from sending any messages
into the Network for between 40 seconds and a
minute and a quarter after he comes alive (this
has been changed from between 30 seconds and a
minute).
2. The IMP has been given the ability to test its Host
interfaces under control of the NCC. This will help
us isolate the trouble when the IMP Host communication
path is faulty.
BC/jm
[ This RFC was put into machine readable form for entry ]
[ into the online RFC archives by BBN Corp. under the ]
[ direction of Alex McKenzie. 12/96 ]
ISO Plain Language
On this page
§1Host Startup Delay
Version 2513 changes how long a host is prevented from sending messages into the network after it comes alive. The new interval is between 40 seconds and one minute 15 seconds, replacing the previous interval of between 30 seconds and one minute.
A host must wait longer after coming alive before sending messages. The new waiting period is between 40 seconds and one minute 15 seconds.
§2Host Interface Testing
The IMP gained the ability to test its host interfaces under control of the Network Control Center. BBN says the test can help isolate trouble when the communication path between an IMP and its host is faulty.
The Network Control Center can ask the IMP to test its connection to a host. The test is intended to help operators locate communication problems.
§3Version 2513
The notice says the new IMP system version would be installed shortly or might already have been installed when the notice was read. It identifies the startup delay and interface test as the two principal changes.
This notice describes two changes planned for IMP version 2513. It does not give additional implementation details.