RFC 270 UNKNOWN INFRASTRUCTURE · CORRECTION

Correction to BBN Report No. 1822 (NIC NO 7958)

A correction to a timeout statement in BBN Report 1822 about the IMP system.

On rfc-editor.org ↗
PUBLISHED
January 1972
AUTHORS
A.M. McKenzie
STREAM
Legacy
DOI
10.17487/RFC0270
ERRATA
Reported errata

RFC text

Original text · RFC Editor View on rfc-editor.org ↗
Network Working Group                                        A. McKenzie
Request for Comments: 270                                            BBN
NIC: 7818                                                January 1, 1972


                    CORRECTION TO BBN REPORT NO. 1822


   In the process of generating RFC #271 we have discovered a set of
   errors in BBN Report No. 1822 (NIC 7958).  The attached page is a
   corrected version of page 25; in addition the first two lines should
   be deleted from page 26.  The paragraph at the top of page 25 is
   changed to show that the Host is NOT marked dead under the stated
   conditions, and to show that the timeout period is 30 (rather than
   40) seconds.  In the footnote, the two changes are underlined; these
   changes also show the timeout period as 30 seconds.  A more formal
   update to Report 1822 will be distributed eventually.

   Please note that these changes reflect errors in previous versions of
   Report 1822, _not_ changes to the IMP system.  The timeout period has
   ALWAYS been 30 seconds and the Host was NEVER marked dead under these
   conditions.
















          [This RFC was put into machine readable form for entry]
      [into the online RFC archives by Kelly Tardif, Viag�nie 10/99]

ISO Plain Language

On this page
PROBLEMBBN found errors in Report 1822's description of when a host is marked dead and how long a timeout lasts.
MECHANISMThe corrected page states that the timeout is 30 seconds and that the host is not marked dead under the stated conditions; two lines on the next page should be deleted.
THE CORRECTIONThe RFC stresses that these are errors in the report, not changes to the IMP system, which already behaved this way.

§1The Report Error

While preparing RFC 271, Alex McKenzie found errors in BBN Report 1822. RFC 270 supplies a corrected version of page 25 and says to remove the first two lines of page 26.

The correction changes the account of the host's status and the length of the timeout described in the report.

A review of another report found that its description did not match the IMP system. This RFC identifies the page that needs correction.

§2The Corrected Timeout

The corrected text says the host is not marked dead under the stated conditions. It also gives the timeout period as 30 seconds rather than 40 seconds.

RFC 270 notes that the timeout was always 30 seconds and that the host was never marked dead in this case.

The report had the wrong timeout and host-status description. The actual behavior was already the corrected version.

§3A Documentation Correction

McKenzie emphasizes that the changes correct earlier versions of Report 1822 and do not change the IMP system. The RFC says a more formal update to the report would be distributed later.

No system change is proposed here. The note fixes the written explanation and says a fuller report revision was planned.